DOWNLOAD
Software Update Notification
-
HDR-9000 PC type OP software V1.1.12019-05-09
-
v1.1.1
Load Last function
able to restore the last deleted data
change date display format
ex) “18/01/30” “Jan/30/2018”
data transmission format bug fix
HDR-mate data
LM, RK button and touch button function bug fix
change masking function
when the chart device setting is HDC-7000 or HDC-9000
the point masking position after row masking moves to the right
change fog values while the program function
the fog values in the program are removed next program step
stabilize bluetooth serial connection
add delay to wait connection
fix bug PD auto set in user settings
additional program edit function
add "others" tab
even if the random chart option is on, do not display random chart in the edit page
custom edit
even if the random chart option is on, do not display random chart in the edit page
add jog dial function setting
settings --> test environment [2] jog button function
settings --> test environment [2] jog button random [on][off]
the above setting allows random chart function to press jog dial button
add axis display option
settings --> test environment [2] horizontal axis setting [0][180]
axis 0 to 180
canon RK-F2 protocol support
only F2 protocol
PC Hub connection
add function keys(bottom of the screen) in the age setting dialog page
21 test function bug fix
PC type OP function
able to adjust CC lens by pressing keyboard
spacebar key
SCA data selection can be done with up and down arrow keys
lens values can be adjust with right and left arrow keys
change windows focus policy
toolbar and mainwindow now activate or deactivate at the same time
system tray icon
admin config --> system setting [3]
change font display with windows dpi setting
single instance application
change auto export function
other huvitz devices can be connected with serial port of the PC without junction box
-
HDR-9000_installer_1.1.1.exe.zip Download
-
HDR Quick guide_HDR-9000_PC SW OP.pdf Download
-
HDR-9000 PC type OP software V1.1.02017-09-19
-
-Random Chart
This function can be used when the random setting [ON].
For temperal usage press Alt button and set RANDOM ON in the function key button.
Press Alt + Set button or wheel click to randomize the VA chart.
Support only HDC-9000PF/N after version 1.2.1.
- Touch Masking
Now, masking operations can be done by clicking the area of the current chart characters.
Support only HDC-9000PF/N after version 1.2.1.
- Control Contrast of the chart
Press Alt button then the Function key buttons below the test view
is changed to CONTRAST+, CONTRAST-
Support only HDC-9000PF/N after version 1.2.1.
- Log
HDR-9000 Operation Panel writes the log files of important processes, communications and button pressed.
Each log files can be exported to USB or specific folder selected.
-
HDR-9000_installer_1.1.0.zip Download
-
HDR Quick guide_HDR-9000_PC SW OP.pdf Download
-
HDR-9000 PC type OP software V1.0.102017-05-17
-
-FIX: Error when prism notation changing from BDBU/BIBO -> r/theta
-FIX: the problem that PD value is not set when reveiving data from RK/LM
-FIX: VA data display problem when the chart type is set to M-type
-FIX: Correct the VA masking behavior in Program Edit/Custom Edit
Correct fog value to be changed correctly
-FIX: fog_val, fog_rg setting item function modification
-FIX: modify input fusion, input stereo, input coincidence [YES][NO] item behavior during the setting동작 수정
-
HDR-9000_installer_1.0.10.exe Download
-
HDR Quick guide_HDR-9000_PC SW OP.pdf Download
-
HDR-9000 PC type OP software V1.0.92016-11-30
-
Modifications
- ADD: chart device support for chinese
-> CDC-9000, CCP-9000
- FIX: the action changed when loading the data from LM and RK
-> Preview without charging lens of transmitted data value and press OK button or SET button to charge lens
-> Fixed to rotate selected item when mouse wheel is input while moving data list in Load menu
- FIX: Receiving Kerato data normally
-> Corrected to display the Kerato Data value of receive data
- ADD: able to recieve the RK and LM data via CAN Box working with HDR-7000 junction box
-
HDR-9000_installer_1.0.9.zip Download
-
HDR Quick guide_HDR-9000_PC SW OP.pdf Download
-
HDR-9000 PC type OP Software V1.0.82016-06-13
-
HDR-9000
- CHANGE: modification VA's size of one of the CDC-4000 C type Number chart.
Only PC type OP Software
- ADD: support various Export function
-> add HDR-Mate Protocol V1.0, V1.1, V1.2(Engineer Mode setting)
- FIX: incorrect Import function.
- ADD: when th PC Software starting up, send reset message to Refractor body.
- ADD: add item on Engineer Mode setting.
-> Delete File After Import
-> Auto Export
-> Export File Name
-> User Defined Export File Name
-> Auto Import Path
-
HDR-9000_installer_1.0.8.zip Download
-
HDR Quick guide_HDR-9000_PC SW OP.pdf Download